-- CISCO-FCC-MIB.my Fibre Channel Congestion Control (FCC) MIB
--
-- Jul 2003, Sanjeev Joshi, Dinkar Sitaram
--
-- Copyright (c) 2003, 2004 by cisco Systems, Inc.
-- All rights reserved.
--
-- *********************************************************************CISCO-FCC-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPE,NOTIFICATION-TYPE,Counter32,Integer32FROM SNMPv2-SMI
MODULE-COMPLIANCE,OBJECT-GROUP,NOTIFICATION-GROUPFROM SNMPv2-CONF
TruthValue,TimeStamp,TEXTUAL-CONVENTIONFROM SNMPv2-TC
ciscoMgmt
FROM CISCO-SMI
ifIndex
FROM IF-MIB
FcAddressId, VsanIndex
FROM CISCO-ST-TC;ciscoFCCMIB MODULE-IDENTITYLAST-UPDATED"200407080000Z"ORGANIZATION"Cisco Systems, Inc."CONTACT-INFO" Cisco Systems
Customer Service
Postal 170 W Tasman Drive
San Jose, CA 95134
USA
Tel +1 800 553-NETS
E-mail cs-san@cisco.com"DESCRIPTION"The MIB module for the management of Fibre Channel
Congestion Control(FCC). FCC is a Cisco proprietary
flow control mechanism that alleviates congestion
on Fibre Channel networks. This MIB enables managers
to configure the FCC mechanism on the switch, provides
statistics of the congestion control packets,
notification of congestion state changes of the
FC port and monitoring of the congestion state of
the FC port."REVISION"200407080000Z"DESCRIPTION"Added the following objects to the 'cFCCPortTable' :
- 'cFCCLastCongestionStartTime' and
- 'cFCCIsRateLimitingApplied'."REVISION"200402250000Z"DESCRIPTION"Changed the cFCCNotificationEnable DEFVAL to 'false'
instead of 1."REVISION"200308060000Z"DESCRIPTION"Changed cFCCCongestionSourceID and
cFCCCongestionDestinationID to be FC_IDs
instead of WWNs and added
cFCCCongestionNotifyVSANIndex"REVISION"200305260000Z"DESCRIPTION"Initial version of this MIB."::={ ciscoMgmt 365}--
-- FCC-MIB object definitions
--ciscoFCCMIBNotifs OBJECTIDENTIFIER::={ ciscoFCCMIB 0}ciscoFCCMIBObjects OBJECTIDENTIFIER::={ ciscoFCCMIB 1}ciscoFCCMIBConformance OBJECTIDENTIFIER::={ ciscoFCCMIB 2}cFCCConfig OBJECTIDENTIFIER::={ ciscoFCCMIBObjects 1}cFCCPortEntries OBJECTIDENTIFIER::={ ciscoFCCMIBObjects 2}cFCCNotifObjects OBJECTIDENTIFIER::={ ciscoFCCMIBObjects 3}
--
-- Textual Conventions
--CiscoFCCCongestionState ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"The FCC Congestion state. This is to indicate the severity
of the Congestion
noCongestion(1) - No Congestion
Congested(2) - Congested
SeverelyCongested(3) - Severely Congested."SYNTAXINTEGER{noCongestion(1),congested (2),severelyCongested(3)}--
-- FCC Configuration
--cFCCEnable OBJECT-TYPESYNTAXINTEGER{enable(1),disable(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"To enable/disable FCC on the device."DEFVAL{ disable }::={ cFCCConfig 1}cFCCPacketPriority OBJECT-TYPESYNTAXInteger32(0..7)MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The traffic Priority for the FCC packets. The generated
FCC quench packets should be granted high, but not
highest priority, so that the FCC packet priority
is higher than the normal data traffic priority but lower
than control and critical traffic priority. This ensures
that the packets of the protocols guaranteeing the
proper behavior of the fabric are not disturbed by
quench packets.
0 is the lowest priority and 7 is the highest."DEFVAL{4}::={ cFCCConfig 2}cFCCNotificationEnable OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This object specifies whether the agent should
generate the notifications defined in this MIB
module.
If the value of this object is 'true', then the
notifications are generated.
If the value of this object is 'false', then the
notifications are not generated."DEFVAL{ false }::={ cFCCConfig 3}--
-- FCC Port Data
--cFCCPortTable OBJECT-TYPESYNTAXSEQUENCEOF CFCCPortEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table providing statistics and status for FCC
on a per FC Port basis."::={ cFCCPortEntries 1}cFCCPortEntry OBJECT-TYPESYNTAX CFCCPortEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry contains the FCC statistics and
status for a particular FC port identified
by the value of ifIndex."INDEX{ ifIndex
}::={ cFCCPortTable 1}
CFCCPortEntry::=
SEQUENCE{
cFCCEdgeQuenchPktsRecd Counter32,
cFCCEdgeQuenchPktsSent Counter32,
cFCCPathQuenchPktsRecd Counter32,
cFCCPathQuenchPktsSent Counter32,
cFCCCurrentCongestionState CiscoFCCCongestionState,
cFCCLastCongestedTime TimeStamp,
cFCCLastCongestionStartTime TimeStamp,
cFCCIsRateLimitingApplied TruthValue}cFCCEdgeQuenchPktsRecd OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Edge Quench packets received and processed
on this Port."::={ cFCCPortEntry 1}cFCCEdgeQuenchPktsSent OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Edge Quench packets generated on this
Port as result of congestion."::={ cFCCPortEntry 2}
cFCCPathQuenchPktsRecd OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Path Quench packets recieved and processed
on this Port."::={ cFCCPortEntry 3}cFCCPathQuenchPktsSent OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Path Quench packets generated on this
Port as result of congestion."::={ cFCCPortEntry 4}cFCCCurrentCongestionState OBJECT-TYPESYNTAX CiscoFCCCongestionState
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The current FCC congestion state of this Port indicating the
severity of the congestion."::={ cFCCPortEntry 5}cFCCLastCongestedTime OBJECT-TYPESYNTAXTimeStamp
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The value of sysUpTime at the most recent time the
congestion state of the Port changed to noCongestion(1)
from some other value. 0 if the congestion state of
the Port has never transitioned to noCongestion(1)
since the last restart of the device."::={ cFCCPortEntry 6}cFCCLastCongestionStartTime OBJECT-TYPESYNTAXTimeStampMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The value of sysUpTime at the most recent time the
congestion state (value of corresponding instance of
'cFCCCurrentCongestionState') of the Port changed from
'noCongestion' to some other value. 0 if the congestion
state of the Port has never transitioned from
'noCongestion' to some other value since the last
restart of the device."::={ cFCCPortEntry 7}cFCCIsRateLimitingApplied OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION
"The value of this object indicates if the rate
limiting is currently being applied on this Port.
If the value of this object is 'true', the rate
limiting is currently being applied on this
Port. If the value of this object is 'false', the
rate limiting is not being applied currently on
this Port."::={ cFCCPortEntry 8}--
-- Objects for notification only
--cFCCCongestionSourceID OBJECT-TYPESYNTAXFcAddressIdMAX-ACCESSaccessible-for-notifySTATUScurrentDESCRIPTION"The FC_ID associated with the Source causing
the congestion. The value is extracted from
the FCC congestion quench packet."::={ cFCCNotifObjects 1}cFCCCongestionDestinationID OBJECT-TYPESYNTAXFcAddressIdMAX-ACCESSaccessible-for-notifySTATUScurrentDESCRIPTION"The FC_ID associated with the Destination that
is part of Source-Destination Flow causing the
congestion. The value is extracted from the
FCC congestion quench packet."::={ cFCCNotifObjects 2}
cFCCCongestionNotifyVSANIndex OBJECT-TYPESYNTAX VsanIndex
MAX-ACCESSaccessible-for-notifySTATUScurrentDESCRIPTION"Id of the VSAN containing the Source-Destination
flow causing the congestion. The value is extracted
from the FCC congestion quench packet. This along
with cFCCCongestionSourceID and
cFCCCongestionDestinationID gives the Flow causing
the congestion."::={ cFCCNotifObjects 3}cFCCCongestionState OBJECT-TYPESYNTAX CiscoFCCCongestionState
MAX-ACCESSaccessible-for-notifySTATUScurrentDESCRIPTION"This is to indicate the congestion state of the port."::={ cFCCNotifObjects 4}--
-- Notifications
--ciscoFCCCongestionStateChange NOTIFICATION-TYPEOBJECTS{ifIndex ,
cFCCCongestionState}STATUScurrentDESCRIPTION"Notification to indicate that the congestion state of
this port has changed. cFCCCongestionState indicates
the new state of the port."::={ ciscoFCCMIBNotifs 1}ciscoFCCCongestionRateLimitStart NOTIFICATION-TYPEOBJECTS{ifIndex,
cFCCCongestionSourceID,
cFCCCongestionDestinationID,
cFCCCongestionNotifyVSANIndex}STATUScurrentDESCRIPTION"Notification to indicate that the rate limiting has
begun on this port for a source-destination pair."::={ ciscoFCCMIBNotifs 2}ciscoFCCCongestionRateLimitEnd NOTIFICATION-TYPEOBJECTS{ifIndex,
cFCCCongestionSourceID,
cFCCCongestionDestinationID,
cFCCCongestionNotifyVSANIndex}STATUScurrentDESCRIPTION"Notification to indicate that the rate limiting has
been stopped on this port for a source-destination
pair."::={ ciscoFCCMIBNotifs 3}--
-- Conformance
--ciscoFCCMIBCompliances OBJECTIDENTIFIER::={ciscoFCCMIBConformance 1}ciscoFCCMIBGroups OBJECTIDENTIFIER::={ciscoFCCMIBConformance 2}ciscoFCCMIBCompliance MODULE-COMPLIANCESTATUSdeprecated-- superseded by-- ciscoFCCMIBComplianceRev1DESCRIPTION"The compliance statement for entities which implement the
CISCO-FCC-MIB."MODULEMANDATORY-GROUPS{cFCCConfigurationGroup,
cFCCPortEntriesGroup,
cFCCNotificationObjectsGroup,
cFCCNotificationGroup}::={ ciscoFCCMIBCompliances 1}ciscoFCCMIBComplianceRev1 MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for entities which implement the
CISCO-FCC-MIB."MODULEMANDATORY-GROUPS{cFCCConfigurationGroup,
cFCCPortEntriesGroupRev1,
cFCCNotificationObjectsGroup,
cFCCNotificationGroup}::={ ciscoFCCMIBCompliances 2}--
-- Units of Conformance
--cFCCConfigurationGroup OBJECT-GROUPOBJECTS{cFCCEnable,
cFCCPacketPriority,
cFCCNotificationEnable}STATUScurrentDESCRIPTION"A collection of objects for FCC configuration."::={ ciscoFCCMIBGroups 1}cFCCPortEntriesGroup OBJECT-GROUPOBJECTS{cFCCEdgeQuenchPktsRecd,
cFCCEdgeQuenchPktsSent,
cFCCPathQuenchPktsRecd,
cFCCPathQuenchPktsSent,
cFCCCurrentCongestionState,
cFCCLastCongestedTime}STATUSdeprecatedDESCRIPTION"A collection of objects for FCC Statistics and Status."::={ ciscoFCCMIBGroups 2}cFCCNotificationObjectsGroup OBJECT-GROUP
OBJECTS{cFCCCongestionDestinationID,
cFCCCongestionSourceID,
cFCCCongestionNotifyVSANIndex,
cFCCCongestionState}STATUScurrentDESCRIPTION"A collection of objects defined for notification only."::={ ciscoFCCMIBGroups 3}cFCCNotificationGroup NOTIFICATION-GROUPNOTIFICATIONS{ciscoFCCCongestionStateChange,
ciscoFCCCongestionRateLimitStart,
ciscoFCCCongestionRateLimitEnd}STATUScurrentDESCRIPTION"A collection of notifications for Congestion Monitoring."::={ ciscoFCCMIBGroups 4}cFCCPortEntriesGroupRev1 OBJECT-GROUPOBJECTS{cFCCEdgeQuenchPktsRecd,
cFCCEdgeQuenchPktsSent,
cFCCPathQuenchPktsRecd,
cFCCPathQuenchPktsSent,
cFCCCurrentCongestionState,
cFCCLastCongestedTime,
cFCCLastCongestionStartTime,
cFCCIsRateLimitingApplied}STATUScurrentDESCRIPTION"A collection of objects for FCC Statistics and Status."::={ ciscoFCCMIBGroups 5}END